HMA EH Series Electric Heaters, are designed specifically to prevent corrosion in the sandblasting and paint application. ENDUSTRI-GM heater as the air flow rate of 1,000 m³ / h to 6,000 m³ / h and a power capacity of 15kW-100kW (51,195BT of-341,350BT) indicates between diversity. Heater fan, the electric motor is a complete unit consisting of a resistor and a power panel.

Technical dataEH-60EH-80EH-100
Heating performance60 kW (34,394 kcal)80 kW (56,124 kcal)100 kW (75,181 kcal)
Air flow rate max.3,000 m³/h4,000 m³/h6,000 m³/h
Air pressure600 hPa  
Blow out temperature max.*60 °C  
Temperature increase (?T) max.60 °C  
Fanradial / 2 kWradial / 2 kWradial / 2 kW
ControlFour-stage switch for air flow rate and temperature
Stufe 0
Air flow rate
Temperature increase (?T)
3,000 m³/h4,000 m³/h6,000 m³/h
Stage 1
Air flow rate
Temperature increase (?T)
3,000 m³/h4,000 m³/h6,000 m³/h
15 °C
Stage 2
Air flow rate
Temperature increase (?T)
3,000 m³/h4,000 m³/h6,000 m³/h
28 °C
Stage 3
Air flow rate
Temperature increase (?T)
3,000 m³/h4,000 m³/h6,000 m³/h
40 °C
Stage 4
Air flow rate
Temperature increase (?T)
3,000 m³/h4,000 m³/h6,000 m³/h
60 °C
Input voltageFour-stage switch for air flow rate and temperature
Power consumption max.75 A (62 kW)112 A (83 kW)162 A (105.5 kW)
Fuse protection / plug78 A / CEE 78 A, 5-pin115 A / CEE 115 A, 5-pin180 A / direct connection
Hose connection ø450 mm  
Suitable for hose lengths up to100 m100 m100 m
Mobilitywheelable/ fork lift / crane
Sound level (distance 3 m)75 dB (A)76 dB (A)78 dB (A)
Minimum cable diameter25 mm²50 mm²85 mm²
Overheat protectionyes
Length1,380 mm1,500 mm2,000 mm
Width800 mm800 mm950 mm
Height1,100 mm1,100 mm1,250 mm
Weight140 kg210 kg300 kg
* the maximum blow out temperature for the standard model is automatically electronically limited to 60 °C . 